SYSMAC C series → MELSEC-Q series small type (C200H/CS/CQM1) : Conversion adapters

ERNT-2CQ216X218X

Features

  • Product overview:
    Upgrade tool products help users to replace an existing programmable controller with a new programmable controller. Since the wiring of the existing programmable controller is used as it is even after replacement, the work time and wiring errors can be reduced significantly.
Sales status On sale

Basic specifications

Item Specifications
Model ERNT-2CQ216X218X
Category Upgrade tool products
Connected device Programmable controllers
Series of connected devices MELSEC-Q
Other PLCs
Product category SYSMAC C series → MELSEC-Q series : Conversion adapter
Slot type 1 slot type
Delivery date -

Specifications

General specifications

Item Specifications


Product specifications

Item Specifications
Product transition selection (1) Before replacement(FCN connector 40P):C200H-ID216,C200H-ID218(*1)
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*2)
Product transition selection (2) Before replacement(connector 40P ×2):C200H-ID217,C200H-ID219(*1)
After replacement(connector 40P ×2):QX41 × 2,QX41-S1 × 2,QX41-S2 × 2(*3)(*4)
Product transition selection (3) Before replacement(connector 40P ×2):C200H-ID111(*1)
After replacement(connector 40P ×2):QX71 × 2(*3)
Product transition selection (4) Before replacement(FCN connector 40P):CS1W-ID231
After replacement(FCN connector 40P):QX41,QX41-S1,
QX41-S2(*5)(*6)
Product transition selection (5) Before replacement(connector 40P ×2):CS1W-ID261
After replacement(connector 40P ×2):QX41 × 2,QX41-S1 × 2,QX41-S2 × 2(*5)(*7)
Product transition selection (6) Before replacement(FCN connector 40P):CS1W-MD261(Input)
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*5)(*6)
Product transition selection (7) Before replacement(FCN connector 40P):CS1W-MD561(Input)
After replacement(FCN connector 40P):QX71(*5)(*8)
Product transition selection (8) Before replacement(FCN connector 40P):CS1W-MD262(Input)
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*5)(*6)
Product transition selection (9) Before replacement(FCN connector 40P):CQM1-ID213,CQM1-ID214
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*9)
Product transition selection (10) Before replacement(FCN connector 40P):CQM1-ID112
After replacement(FCN connector 40P):QX71
Product transition selection (11) Before replacement(FCN connector 40P):CJ1W-ID231
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*5)(*6)(*9)
Product transition selection (12) Before replacement(connector 40P ×2):CJ1W-ID261
After replacement(connector 40P ×2):RQX41 × 2,QX41-S1 × 2,QX41-S2 × 2(*5)(*6)(*9)
Product transition selection (13) Before replacement (FCN connector 40P):CJ1W-MD261 (Input)
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2(*5)(*6)(*9)
Precautions *1:SYSMAC C series modules with "-N" at the end of their model name are not listed because only the difference is whether a connector is included or not.
*2:If the existing module uses 24VDC negative common, consider rewiring to the QX81 or QX81-S2.
*3:For replacement, two MELSEC-Q series modules and two conversion adapters are required.
*4:If the existing module uses 24VDC negative common, consider rewiring to the QX82 or QX82-S2.
*5:Since the number of points per common changes (16 points/common → 32 points/common), check the common terminal connection of the module before replacement.
*6:If the existing module uses a different power supply for each 16-point group, consider rewiring to multiple QX40s or multiple QX80s.
If the existing module uses negative common, consider rewiring to the QX81 or QX81-S2.
*7: For replacement, two MELSEC-Q series modules and two conversion adapters are required.
If the existing module uses a different power supply for each 16-point group, consider rewiring to four QX40s or four QX80s.
If the existing module uses negative common, consider rewiring to the QX82 or QX82-S1.
*8: If the existing module uses a different power supply for each 16-point group, consider rewiring to two QY40Ps or two QY70s.
*9: If the existing module uses negative common, consider rewiring to the QX81 or QX81-S2.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Upgrade Tool Products(23MB) English MEIC206E_20Y-C July 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User’s Manual(598KB) English 50CM-D180288E-B September 2020

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview

Related products

N/A