Panel mount HMI speaker

FA1-GT0S04W

Features

  • Product overview:
    The speaker notifies important information accurately to the operator away from
    the GOT. The servicing/maintenance/work efficiency will thus improve.
    (The sound output function works while the GOT is in screen saver mode.)
    Merit.1
    When a touch switch is pressed, the next operation
    and precautions are voiced, which prevents incorrect
    operation.
    Merit.2
    Attaching the speaker from the front and back of the panel completes the installation.
    The speaker and the GOT surfaces are flush with the panel surface.
    Merit.3
    The speaker is suited for use in the factory environment.
    Merit.4
    The volume can be adjusted in 10 levels (90 dB max.)
    depending on the worksite environment.
Sales status On sale

Basic specifications

Item Specifications
Model FA1-GT0S04W
Category For system maintenance
Connected devices HMI(GOT)
MELIPC
Series of connected devices GOT2000 series
GOT1000 series
MELIPC MI 5000 series
MELIPC MI 3000 series
MELIPC MI 1000 series
Product category Utilization of HMI and voice output function

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55°C
Storage ambient temperature -15 to +60 °C
Operating ambient humidity 10 to 90% RH, non-freezing
Storage ambient humidity 10 to 90% RH, non-freezing
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2 (15 G), 3 sweeps each in X, Y, and Z directions)
Operating atmosphere No greasy fumes, corrosive gas, flammable gas, and excessive conductive dust
Operating altitude *1 2000 m or less
Installation location Inside the control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
IP protection level IP2X
Weight 175 g
Installation (Installation method) Interposing the panel
Installation (Installation hole processing dimensions) Φ30 +1-0 mm
Installation (Applicable panel thickness) 1.5 to 6 mm
Power supply to the built-in amplifier Power supply voltage : 24 V DC +20%, -15%
Current consumption : 0.28 A
Wiring method : Wiring to the supplied power supply connector
Applicable wire size : 0.2 to 2.5 mm2 (AWG 12 to 24)
Sound ( Input terminal ) Φ3.5 minijack
Sound ( Maximum output ) 3.5 W
Sound ( Sound pressure level ) 90 dB max. at 1 m *1
Sound ( Volume control ) 10 levels (Use the rotary switch of the speaker.)
Connectable GOT2000 series (manufactured by Mitsubishi Electric Corporation) GT25 wide models with a built-in sound output interface Rugged GT25 model used where a panel mount speaker is usable. GT27 models, GT25 models except GT2505-VTBD, GT25 open frame models *2
Connectable GOT1000 series (manufactured by Mitsubishi Electric Corporation) GT16 models, GT15 models *2
Connectable MELIPCs (manufactured by Mitsubishi Electric Corporation) MELIPC MI3000 with a built-in sound output interface, MELIPC MI5000, MI1000 *3
Precautions *1 : Equivalent to the noise of railroad underpasses
*2 : Sound output unit (GT15-SOUT) needs to be mounted on the extension interface.
*3 : HDMI splitter with an aux. port needs to be connected.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Panel Mount HMI Speaker(2MB) English MEIC187E_204-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Purpose-Specific Products(40MB) English MEIC204E_20Y-B July 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User’s Manual(1MB) English 50D-FG0438E-A October 2020

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview

Related products

N/A