MELSEC-dedicated common terminal block

FA1-TESV38COM

Features

  • Product overview:
    The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
    Merit.1
    The vertical type terminal block contributes to downsizing of system.
    Merit.2
    Retightening work is not required at periodic inspection, as screws do not loose due to vibration.
    Merit.3
    A device such as a 3-wire sensor can be easily connected by placing the common terminal block next to the spring clamp type junction terminal block.
    Merit.4
    Using ferrule terminals enables push-in connections.
Sales status Discontinued(3/D/YYYY)

Basic specifications

Item Specifications
Model FA1-TESV38COM
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC iQ-F
MELSEC-Q
MELSEC-F
MELSEC-L
Product category Junction terminal block for programmable controller
Terminal block type Spring clamp terminal type

Specifications

General specifications

Item Specifications
Operating ambient temperature -20 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
Rated voltage 24VDC (Class2 or SELV+LIM) *1/100 to 240VAC (+10%, -15%), 50/60Hz
Maximum operating voltage 30VDC (Class2 or SELV+LIM) *2/264VAC
Maximum operating current Common: 6A *3
Wiring method for common 19 common points + 19 common points
Terminal block : Number of terminals 38
Terminal block : Applicable wire *1,4 0.2 to 1.5mm2 (24 to 16AWG)*5, sheath: φ2.8mm or less
Terminal block : Wire strip length 8 to 9mm (Maximum sheath outside diameter: φ2.8mm or less)
Module installation Applicable DIN rails: TH35-7.5Fe, TH35-7.5AL (IEC 60715 compliant)
Withstand voltage, insulation resistance 500VAC for 1 minute, 10MΩ or more (measured with 500VDC insulation resistance tester)
Weight Approx. 60g
Precautions *1: Select cables depending on the current value used.
*2: Use a Class2 power supply or an SELV (Safety Extra-Low Voltage) circuit and LIM (Limited Energy Circuit) power supply.
*3: Evaluation for UL certification is conducted using a resistance load as a condition.
*4: Evaluation for UL certification is conducted with copper wires.
*5: For a wire to be connected to a terminal block, use a copper wire whose temperature standard is 75°C or higher.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
MELSEC-Dedicated Small-Size Type Spring Clamp Terminal Block Modules(1MB) English MEIC150E_187 July 2020
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User’s Manual(1MB) English 50D-FG0081E-E September 2020
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview

Related products

N/A