- New Satellite series small type (JW300/30H/20H) → MELSEC-Q series
ERNT-2JQ234N264N
- Features
- Specifications
- External Dimensions・
Product CAD Data - Wiring diagrams and connection examples・
Note - Catalogs・
New Product Releases - Manual
- Technical information
(Technical News) - Downloads
- Video
- Related products
Features
-
- Product overview:
- Upgrade tool products help users to replace an existing programmable controller with a new programmable controller. Since the wiring of the existing programmable controller is used as it is even after replacement, the work time and wiring errors can be reduced significantly.
Sales status | On sale |
---|
Basic specifications
Item | Specifications | |
---|---|---|
Model | ERNT-2JQ234N264N | |
Category | Upgrade tool products | |
Connected device | Programmable controllers | |
Series of connected devices | MELSEC-Q | |
Other PLCs | ||
Product category | New Satellite JW series → MELSEC-Q series : Conversion adapter | |
Slot type | 1 slot type | |
Delivery date | - |
Specifications
General specifications
Item | Specifications |
---|
Product specifications
Item | Specifications | |
---|---|---|
Product transition selection (1) | Before replacement(FCN connector 40P):JW-234N | |
After replacement(FCN connector 40P):QX41,QX41-S1,QX41-S2,QX71(*1)(*2) | ||
Product transition selection (2) | Before replacement(connector 40P ×2):JW-264N | |
After replacement(connector 40P ×2):QX41×2台,QX41-S1×2台,QX41-S2×2台(*3)(*4)(*5) | ||
Precautions | *1: If the existing module uses 24VDC negative common, consider rewiring to the QX81 or QX81-S2. | |
*2: If the existing module uses a different power supply for each 16-point group, consider rewiring to two QX40s, two QX40-S1s, two QX70s, or two QX80s. When rewiring, consider using the ERNT-ASQTB20. |
||
*3: Negative common input is not supported. | ||
*4: If the existing module uses 24VDC negative common, consider rewiring to the QX82 or QX82-S1. | ||
*5: For replacement, two conversion adapters are required. |
External Dimensions・Product CAD Data
External Dimensions
Product CAD Data
Wiring diagrams and connection examples・Note
Wiring diagrams and connection examples
N/A
Name | Filename |
---|
Other Technical Information
N/A
Name | Filename |
---|
Precautions for use
N/A
Name | Filename |
---|
Catalogs・New Product Releases
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
Easy Replacement from SHARP PLC to Mitsubishi Electric MELSEC series(947KB) | English | MEIC228E_227 | July 2022 |
FA Goods General Catalog Digest edition(28MB) | English | MEIC198E_209-B | March 2024 |
FA关联产品 综合目录 摘要版(29MB) | Simplified Chinese | MEIC199C_209-B | March 2024 |
FA Goods General Catalog Upgrade Tool Products(23MB) | English | MEIC206E_20Y-C | July 2024 |
Manual
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
User’s Manual(1MB) | English | 50CM-D180265E-B | September 2020 |
Technical information(Technical News)
N/A
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|
Downloads
N/A
Profile/module FB (function block)
Name | Filename |
---|
Control & Communication System Profile CSP+
Name | Filename |
---|
Sample program
Name | Filename |
---|
Video
N/A
Related products
Connection cables
Model | Length | Name | Overview |
---|
Related products
N/A