[Output type] Module installation base unit

FA-ATB8YTB

Features

  • Product overview:
    Analog signals from the connected devices such as sensors can be converted to signals suitable for a programmable controller (example: from a temperature signal to a voltage signal). Data from sensors can be visualized easily, and small-scale IoT can be introduced.
    Merit.1
    Thick wires such as compensating lead wires can be directly connected.
    Merit.2
    Isolation between channels enables mixing of input modules.
    Merit.3
    This product is used with a conversion adapter.
Sales status On sale

Basic specifications

Item Specifications
Model FA-ATB8YTB
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC-Q
MELSEC-L
MELSEC-F
CC-Link IE TSN
CC-Link IE Field
CC-Link
Other PLC
Computers from various manufacturers
Product category Analog signal converter
Terminal block type Screw terminal type
Delivery date -

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside the control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
No. of slots 8
Terminal block : Terminal screw M3 spring-up screws, 7.62mm pitch
Terminal block : Applicable wire,
tightening torque
0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N・cm (6 to 9kgf・cm)
Module installation : Screw type M4 × 0.7mm × 20mm or more
Tightening torque: 78 to 118N・cm (8 to 12kgf・cm)
Module installation : DIN rail Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC 60715 compliant)
Power supply 24VDC+-10%
Current consumption (24VDC) 6mA or less
(not including current consumption of modules, the programmable controller, and the monitor device)
Withstand voltage, insulation resistance Between input, output, and power supply: 750VAC for 1 minute, 10MΩ or more
Weight Approx. 320g
Precautions Mount a dummy module into an unused slot to allow no empty slot.
When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.
When the programmable controller's output is between 4 and 20mA and the FA-ATFTMXY signal pass-through module is used, the voltage value corresponding to the input resistance of the connected device is detected as a monitor output.
The current value can be calculated by dividing the detected voltage by the input resistance.
When connecting the product with a programmable controller, confirm that the product configuration is correct.
Connection based on a wrong configuration may cause a failure or malfunction.
Output type modules (line color: orange) only can be mounted. Mounting an input type module may cause a failure or malfunction.
Mount modules according to the signals of an external device. Incorrect module mounting may cause a failure or malfunction.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Analog Signal Converters(2MB) English MEIC220E_21Y-B February 2025
模拟信号转换器 (2MB) Simplified Chinese MEIC235C_23X-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User’s Manual(1MB) English 50D-FA9010-123E-F December 2023
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview

Related products

Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
FA-BAR20PG-20

The required number of short-circuit bars can be easily cut out along cutting lines.

Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
FA-BAR20P-20

The required number of short-circuit bars can be easily cut out along cutting lines.