[Input type] Conversion adapter (1 input - 2 current outputs supported)

FA-ATKAA8XM

Features

  • Product overview:
    Analog signals from the connected devices such as sensors can be
    converted to signals suitable for a programmable controller (example:
    from a temperature signal to a voltage signal).
    Data from sensors can be visualized easily, and small-scale IoT can be
    introduced.
    Merit.1
    This product is used with a module installation base unit (FA-ATKB8XTB).
    Merit.2
    Reliability is improved by isolation between output 1 (programmable controller side) and output 2 (recorder connected side).
Sales status On sale

Basic specifications

Item Specifications
Model FA-ATKAA8XM
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC-Q
MELSEC-L
MELSEC iQ-F
MELSEC-F
CC-Link IE TSN
CC-Link IE Field
CC-Link
Other PLC
Computers from various manufacturers
Product category Analog signal converter
Terminal block type Screw terminal type
Delivery date -

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside the control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
No. of points 8 (8 channel)
Input : Input signal 1 to 5V (module output)
Accuracy(percentage of full scale) : Reference accuracy +-0.1% or less (surrounding air temperature: 25°C+-5°C)( The table shows the specifications for an adapter alone. The accuracy of modules to be mounted should be added. ) *1
Accuracy(percentage of full scale) : Temperature characteristics +-0.015%/°C or less
Output 1(OUT1) (programmable controller side) : Interface 20-pin MIL connector
Output 1(OUT1) (programmable controller side) : Output signal 4 to 20mA
Output 1(OUT1) (programmable controller side) : Output allowable load resistance 250 to 350Ω
Output 1(OUT1) (programmable controller side) : Isolation between input and output Not provided
Output 1(OUT1) (programmable controller side) : Isolation between output channels Not provided
Output 2 (OUT2) : Interface Through FA-ATKB8XTB OUT2 (M3 spring-up screws, 7.62mm pitch)
Output 2 (OUT2) : Output signal 4 to 20mA
Output 2 (OUT2) : Output allowable load resistance 600Ω or less *Operating temperature range restricted
Output 2 (OUT2) : Isolation between input and output Transformer
Output 2 (OUT2) : Isolation between output channels Provided
Response speed 10ms or less( Time from when a startup pulse is input until the output level reaches 90% ) *2
Power supply 24VDC+-10% (Supplied from the installation base unit)
Current consumption (24VDC) 310mA or less
Withstand voltage, insulation resistance Between input, all outputs for output 1, each channel for output 2, and power supply:
750VAC for 1 minute, 10MΩ or more
Mounting screw tightening torque
for installation base unit
36 to 48N・cm (3.7 to 4.8kgf・cm)
Weight Approx. 200g
Precautions When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.
A pass-through module (FA-ATFTMXY) can be used for voltage input only.
When connecting the product with a programmable controller, confirm that the product configuration is correct. Connection based on a wrong configuration may cause a failure or malfunction.
*1 The table shows the specifications for an adapter alone. The accuracy of modules to be mounted should be added.
*2 Time from when a startup pulse is input until the output level reaches 90%

External Dimensions・Product CAD Data

External Dimensions

N/A

Name Filename

Product CAD Data

N/A

Name Filename

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Analog Signal Converters(2MB) English MEIC220E_21Y-B February 2025
模拟信号转换器 (2MB) Simplified Chinese MEIC235C_23X-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User's Manual Analog Signal Conversion Module (Input type)(2MB) English 50D-FA9010-122E-G December 2023
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview

Related products

N/A