- [Input type] Module installation base unit (with connector for adapter)
FA-ATKB8XTB
- Features
- Specifications
- External Dimensions・
Product CAD Data - Wiring diagrams and connection examples・
Note - Catalogs・
New Product Releases - Manual
- Technical information
(Technical News) - Downloads
- Video
- Related products
Features
-
- Product overview:
-
Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.
- Merit.1
- Thick wires such as compensating lead wires can be directly connected.
- Merit.2
- Isolation between channels enables mixing of input modules.
- Merit.3
- This product is used with a conversion adapter.
Sales status | On sale |
---|
Basic specifications
Item | Specifications | |
---|---|---|
Model | FA-ATKB8XTB | |
Category | Time and wire saving devices | |
Connected device | Programmable controller | |
Series of connected devices | MELSEC iQ-R | |
MELSEC-Q | ||
MELSEC-L | ||
MELSEC iQ-F | ||
MELSEC-F | ||
CC-Link IE TSN | ||
CC-Link IE Field | ||
CC-Link | ||
Other PLC | ||
Computers from various manufacturers | ||
Product category | Analog signal converter | |
Terminal block type | Screw terminal type | |
Delivery date | - |
Specifications
General specifications
Item | Specifications | |
---|---|---|
Operating ambient temperature | 0 to 55℃ | |
Storage ambient temperature | -25 to 75℃ | |
Operating ambient humidity | 5 to 95%RH, no condensation | |
Storage ambient humidity | 5 to 95%RH, no condensation | |
Vibration resistance ( With intermittent vibration ) | 5 to 8.4Hz : Half amplitude 3.5mm | |
8.4 to 150Hz : Acceleration 9.8m/s2 | ||
Number of sweeps : 10 times in each direction X, Y, and Z | ||
Vibration resistance ( With continual vibration ) | 5 to 8.4Hz : Half amplitude 1.75mm | |
8.4 to 150Hz : Acceleration 4.9m/s2 | ||
Shock resistance | 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2) | |
Operating atmosphere | Free of corrosive gases | |
Operating altitude *1 | 2000m or less | |
Installation location | Inside the control panel | |
Overvoltage category *2 | II or less | |
Pollution degree *3 | 2 or less | |
Precautions | *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using the module under pressure, please consult your local Mitsubishi Electric representative. |
|
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V. | ||
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive pollution occurs. A temporary conductivity caused by condensation must be expected occasionally. |
Product specifications
Item | Specifications | |
---|---|---|
No. of slots | 8 | |
Terminal block : Terminal screw | M3 spring-up screws, 7.62mm pitch | |
Terminal block : Applicable wire, tightening torque | 0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N・cm (6 to 9kgf・cm) | |
Module installation : Screw type | M4 × 0.7mm × 20mm or more Tightening torque: 78 to 118N・cm (8 to 12kgf・cm) |
|
Module installation : DIN rail | Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC 60715 compliant) | |
Power supply | 24VDC+-10% | |
Current consumption (24VDC) | 6mA or less (not including current consumption of a conversion adapter and modules) |
|
Withstand voltage, insulation resistance | Between input, output, and power supply: 750VAC for 1 minute, 10MΩ or more | |
Weight | Approx. 370g | |
Precautions | Mount a dummy module into an unused slot to allow no empty slot. | |
Even when cables are connected, the size in the height direction falls within the specified external dimensions. | ||
Input type modules (line color: purple) only can be mounted. Mounting an output type module may cause a failure or malfunction. | ||
Mount modules according to the signals of an external device. Incorrect module mounting may cause a failure or malfunction. |
External Dimensions・Product CAD Data
External Dimensions
Name | Filename |
---|---|
Dimensions(128KB) | sales_fa_meefan_fa-atkb8xtb_outline_1.pdf |
Product CAD Data
Name | Filename |
---|---|
Dimensions(CAD 2D) | sales_fa_meefan_fa-atkb8xtb.dxf(5MB) |
Wiring diagrams and connection examples・Note
Wiring diagrams and connection examples
N/A
Name | Filename |
---|
Other Technical Information
N/A
Name | Filename |
---|
Precautions for use
N/A
Name | Filename |
---|
Catalogs・New Product Releases
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
Analog Signal Converters(2MB) | English | MEIC220E_21Y-B | February 2025 |
模拟信号转换器 (2MB) | Simplified Chinese | MEIC235C_23X-A | February 2025 |
FA Goods General Catalog Digest edition(28MB) | English | MEIC198E_209-B | March 2024 |
FA关联产品 综合目录 摘要版(29MB) | Simplified Chinese | MEIC199C_209-B | March 2024 |
FA Goods General Catalog Time and Wire Saving Devices(79MB) | English | MEIC202E_20Z-E | November 2024 |
Manual
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
User's Manual Analog Signal Conversion Module (Input type)(2MB) | English | 50D-FA9010-122E-G | December 2023 |
EMC and Low Voltage Directives Compliant Manual(256KB) | English | 50D-FA9010-108E-G | December 2023 |
Technical information(Technical News)
N/A
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|
Downloads
N/A
Profile/module FB (function block)
Name | Filename |
---|
Control & Communication System Profile CSP+
Name | Filename |
---|
Sample program
Name | Filename |
---|
Video
N/A
Related products
Connection cables
Model | Length | Name | Overview |
---|
Related products
- Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
- FA-BAR20P-20
The required number of short-circuit bars can be easily cut out along cutting lines.
- Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
- FA-BAR20PG-20
The required number of short-circuit bars can be easily cut out along cutting lines.