MELSEC-dedicated 32-point 3-wire open type with 3-pole connector

FA-LEB32XY-3

Features

  • Product overview:
    The junction terminal block helps signal transmissions between a
    programmable controller and devices such as sensors in connection
    methods suitable for applications.
    Merit.1
    32-point I/O signals from a programmable controller are converted into 32-point e-CON connector outputs.
    Merit.2
    Cables (26 to 20AWG) from a 2-wire/3-wire sensor can be pushed into e-CON connectors collectively using a tool such as pliers. Sheaths need not be stripped.
    Merit.3
    e-CON connectors can be easily inserted into/removed from sockets using the lever. When a connector is inserted, it will be locked by the lever.
    Merit.4
    Cross-head screws of the power supply terminals are spring-up screws, making round solderless terminal installation easy.
    Merit.5
    The Mitsubishi Electric programmable controller input/output signal (0 to 1F) numbers are assigned to modules.
    Merit.6
    DIN rail installation and screw installation are available. When units are installed to a DIN rail side by side, the base of a unit will be under the next unit body.
Sales status On sale

Basic specifications

Item Specifications
Model FA-LEB32XY-3
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC-Q
MELSEC-L
Product category Junction terminal block for programmable controller
Terminal block type e-CON

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
Rated voltage 24VDC
Voltage 28.8VDC
Current 1A (each signal terminal), 2A (power supply terminal)
e-CON connector : 3-pole connector 1P: 24VDC, 2P: 0V, 3P: X/Y
e-CON connector : Applicable wire Applicable wire: 0.14 to 0.5mm2 (#26 to #20AWG)
Finishing outer diameter: 0.8 to 2.0mm (Initial contact resistance: 50mΩ or less)
e-CON connector : Wiring method for common: 32 points/32 (24V) common points + 32 (0V) common points
Module installation : Screw type M3 screw, number of terminals: 2P, spring-up screw with finger protection cover
Module installation : DIN rail 0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N-cm (6 to 9kgf-cm)
Installation method : Screw type M4 × 0.7mm × 10mm or more, tightening torque: 78 to 118N-cm (8 to 12kgf-cm)
Installation method : DIN rail Applicable DIN rails: TH35-7.5Fe, TH35-7.5AL (IEC 60715 compliant)
No. of points 32
I/O device No. X0 to X1F or Y0 to Y1F
Withstand voltage, insulation resistance 500VAC for 1 minute, 10MΩ or more
(between all DC external terminals and ground, between charged areas)
Weight Approx. 100g
Precautions X or Y of the input/output device number is X when an input module is connected, and Y when an output module is connected. The number is determined by the slot where the I/O module is inserted.
When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User's Manual(1MB) English 50D-FG0229E-A October 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview
FA-CBL200FMV 20m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL150FMV 15m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FMVE 3m For MELSEC negative common input (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FMVE 2m For MELSEC negative common input (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50DMFX 5m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30DMFX 3m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20DMFX 2m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10DMFX 1m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL05DMFX 0.5m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FMVE 1m For MELSEC negative common input (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL05FMVE 0.5m For MELSEC negative common input (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100DMFY 10m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50DMFY 5m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30DMFY 3m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL05DMFY 0.5m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20DMFY 2m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10DMFY 1m For MELSEC source output (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100DMFX 10m For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-FCBL30FMH 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-FCBL20FMH 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-FCBL10FMH 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-FCBL05FMH 0.5m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FMH 5m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FMH 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FMH 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FMH 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL05FMH 0.5m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL80FMV 8m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100FMV 10m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FMV 5m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FMV 3m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FMV 2m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FMV 1m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL05FMV 0.5m For MELSEC positive common input/sink output
(FCN 40P connector and MIL 40P connector)
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.

Related products

N/A