- MELSEC-dedicated 32-point 3-wire open type with 3-pole connector
FA-LEB32XY-3
- Features
- Specifications
- External Dimensions・
Product CAD Data - Wiring diagrams and connection examples・
Note - Catalogs・
New Product Releases - Manual
- Technical information
(Technical News) - Downloads
- Video
- Related products
Features
-
- Product overview:
-
The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.
- Merit.1
- 32-point I/O signals from a programmable controller are converted into 32-point e-CON connector outputs.
- Merit.2
- Cables (26 to 20AWG) from a 2-wire/3-wire sensor can be pushed into e-CON connectors collectively using a tool such as pliers. Sheaths need not be stripped.
- Merit.3
- e-CON connectors can be easily inserted into/removed from sockets using the lever. When a connector is inserted, it will be locked by the lever.
- Merit.4
- Cross-head screws of the power supply terminals are spring-up screws, making round solderless terminal installation easy.
- Merit.5
- The Mitsubishi Electric programmable controller input/output signal (0 to 1F) numbers are assigned to modules.
- Merit.6
- DIN rail installation and screw installation are available. When units are installed to a DIN rail side by side, the base of a unit will be under the next unit body.
Sales status | On sale |
---|
Basic specifications
Item | Specifications | |
---|---|---|
Model | FA-LEB32XY-3 | |
Category | Time and wire saving devices | |
Connected device | Programmable controller | |
Series of connected devices | MELSEC iQ-R | |
MELSEC-Q | ||
MELSEC-L | ||
Product category | Junction terminal block for programmable controller | |
Terminal block type | e-CON |
Specifications
General specifications
Item | Specifications | |
---|---|---|
Operating ambient temperature | 0 to 55℃ | |
Storage ambient temperature | -25 to 75℃ | |
Operating ambient humidity | 5 to 95%RH, no condensation | |
Storage ambient humidity | 5 to 95%RH, no condensation | |
Vibration resistance ( With intermittent vibration ) | 5 to 8.4Hz : Half amplitude 3.5mm | |
8.4 to 150Hz : Acceleration 9.8m/s2 | ||
Number of sweeps : 10 times in each direction X, Y, and Z | ||
Vibration resistance ( With continual vibration ) | 5 to 8.4Hz : Half amplitude 1.75mm | |
8.4 to 150Hz : Acceleration 4.9m/s2 | ||
Shock resistance | 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2) | |
Operating atmosphere | Free of corrosive gases | |
Operating altitude *1 | 2000m or less | |
Installation location | Inside control panel | |
Overvoltage category *2 | II or less | |
Pollution degree *3 | 2 or less | |
Precautions | *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using the module under pressure, please consult your local Mitsubishi Electric representative. |
|
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V. | ||
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive pollution occurs. A temporary conductivity caused by condensation must be expected occasionally. |
Product specifications
Item | Specifications | |
---|---|---|
Rated voltage | 24VDC | |
Voltage | 28.8VDC | |
Current | 1A (each signal terminal), 2A (power supply terminal) | |
e-CON connector : 3-pole connector | 1P: 24VDC, 2P: 0V, 3P: X/Y | |
e-CON connector : Applicable wire | Applicable wire: 0.14 to 0.5mm2 (#26 to #20AWG) Finishing outer diameter: 0.8 to 2.0mm (Initial contact resistance: 50mΩ or less) |
|
e-CON connector : Wiring method for common: | 32 points/32 (24V) common points + 32 (0V) common points | |
Module installation : Screw type | M3 screw, number of terminals: 2P, spring-up screw with finger protection cover | |
Module installation : DIN rail | 0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N-cm (6 to 9kgf-cm) | |
Installation method : Screw type | M4 × 0.7mm × 10mm or more, tightening torque: 78 to 118N-cm (8 to 12kgf-cm) | |
Installation method : DIN rail | Applicable DIN rails: TH35-7.5Fe, TH35-7.5AL (IEC 60715 compliant) | |
No. of points | 32 | |
I/O device No. | X0 to X1F or Y0 to Y1F | |
Withstand voltage, insulation resistance | 500VAC for 1 minute, 10MΩ or more (between all DC external terminals and ground, between charged areas) |
|
Weight | Approx. 100g | |
Precautions | X or Y of the input/output device number is X when an input module is connected, and Y when an output module is connected. The number is determined by the slot where the I/O module is inserted. | |
When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact. |
External Dimensions・Product CAD Data
External Dimensions
Name | Filename |
---|---|
Dimensions(52KB) | sales_fa_meefan_fa-leb32xy-3_outline_1.pdf |
Product CAD Data
Name | Filename |
---|---|
Dimensions(CAD 2D) | sales_fa_meefan_fa-leb32xy-3.dxf(1MB) |
Wiring diagrams and connection examples・Note
Wiring diagrams and connection examples
N/A
Name | Filename |
---|
Other Technical Information
N/A
Name | Filename |
---|
Precautions for use
N/A
Name | Filename |
---|
Catalogs・New Product Releases
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
FA Goods General Catalog Digest edition(28MB) | English | MEIC198E_209-B | March 2024 |
FA关联产品 综合目录 摘要版(29MB) | Simplified Chinese | MEIC199C_209-B | March 2024 |
FA Goods General Catalog Time and Wire Saving Devices(79MB) | English | MEIC202E_20Z-E | November 2024 |
Manual
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|---|---|---|
User's Manual(1MB) | English | 50D-FG0229E-A | October 2023 |
Technical information(Technical News)
N/A
* The table can be scrolled to the right.
Name | Language | Document No. | Release date |
---|
Downloads
N/A
Profile/module FB (function block)
Name | Filename |
---|
Control & Communication System Profile CSP+
Name | Filename |
---|
Sample program
Name | Filename |
---|
Video
N/A
Related products
Connection cables
Model | Length | Name | Overview |
---|---|---|---|
FA-CBL200FMV | 20m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL150FMV | 15m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL30FMVE | 3m | For MELSEC negative common input (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL20FMVE | 2m | For MELSEC negative common input (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL50DMFX | 5m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL30DMFX | 3m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL20DMFX | 2m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL10DMFX | 1m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL05DMFX | 0.5m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL10FMVE | 1m | For MELSEC negative common input (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL05FMVE | 0.5m | For MELSEC negative common input (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL100DMFY | 10m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL50DMFY | 5m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL30DMFY | 3m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL05DMFY | 0.5m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL20DMFY | 2m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL10DMFY | 1m | For MELSEC source output (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL100DMFX | 10m | For MELSEC negative common input (D-Sub 37P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-FCBL30FMH | 3m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-FCBL20FMH | 2m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-FCBL10FMH | 1m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-FCBL05FMH | 0.5m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (with flat cable) (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL50FMH | 5m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL30FMH | 3m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL20FMH | 2m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL10FMH | 1m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL05FMH | 0.5m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module or general-purpose type for OMRON's PLCs (FCN 40P connector and MIL 40P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL80FMV | 8m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL100FMV | 10m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL50FMV | 5m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL30FMV | 3m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL20FMV | 2m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL10FMV | 1m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
FA-CBL05FMV | 0.5m | For MELSEC positive common input/sink output (FCN 40P connector and MIL 40P connector) |
Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
Related products
N/A