[Output type] Voltage to current signal conversion module

FA-ATSVM1YA020

Features

  • Product overview:
    Analog signals from the connected devices such as sensors can be
    converted to signals suitable for a programmable controller (example:
    from a temperature signal to a voltage signal).
    Data from sensors can be visualized easily, and small-scale IoT can be
    introduced.
    Merit.1
    This module converts the range of a voltage input, and outputs it. (Isolation between input and output is provided.)
    Merit.2
    The module can be mounted/removed to/from an installation base unit easily.
Sales status On sale

Basic specifications

Item Specifications
Model FA-ATSVM1YA020
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC-Q
MELSEC-L
Analog signal converter
Terminal block type Screw terminal type
Delivery date -

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
No. of points 1 (1 channel)
Input (programmable controller side) : Input range 1 to 5V
Input (programmable controller side) : Input resistance 1MΩ or more
Accuracy(percentage of full scale) : Reference accuracy +-0.1% or less (surrounding air temperature: 25°C+-5°C)
Accuracy(percentage of full scale) : Temperature characteristics +-0.015%/°C or less
Output : Output signal 0 to 20mA
Output : Output allowable load resistance 600Ω or less
Output : Disconnection detection function Unavailable
Response speed 15ms or less
( Time from when a startup pulse is input until the output level reaches 90% )
Zero/span adjustment Zero adjustment range: -2 to 2%, span adjustment range: 98 to 102%
Power supply 24VDC+-10% (Supplied from the installation base unit)
Current consumption (24VDC) 45mA or less
Insulation method Transformer
Withstand voltage, insulation resistance Between input, output, and power supply: 750VAC for 1 minute, 10MΩ or more
Quantity 1
Weight Approx. 40g

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

N/A

Name Filename

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Analog Signal Converters(2MB) English MEIC220E_21Y-B February 2025
模拟信号转换器 (2MB) Simplified Chinese MEIC235C_23X-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User’s Manual(1MB) English 50D-FA9010-123E-F December 2023
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview
FA-CBL10ATQ8YA 1.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20ATQ8YA 2.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10ATYF 1.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATYF 3.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20ATYF 2.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATQ8YT 3.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10ATQ8YT 1.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20ATQ8YT 2.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATQ8YA 3.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.

Related products

[Input/output type] Signal pass-through module
FA-ATFTMXY

Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.

Terminal block to connector conversion adapter
FA-Q6TCA

Analog signals from the connected devices such as sensors can be converted to signals suitable for a programmable controller (example: from a temperature signal to a voltage signal). Data from sensors can be visualized easily, and small-scale IoT can be introduced.

[Output type] Module installation base unit
FA-ATB8YTB

Analog signals from the connected devices such as sensors can be converted to signals suitable for a programmable controller (example: from a temperature signal to a voltage signal). Data from sensors can be visualized easily, and small-scale IoT can be introduced.

[Input/output type] Dummy module
FA-ATNDM5

Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.

Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
FA-BAR20PG-20

The required number of short-circuit bars can be easily cut out along cutting lines.

Short-circuit bar for 7.62mm pitch M3-screw terminal block(with/without insulating coating)
FA-BAR20P-20

The required number of short-circuit bars can be easily cut out along cutting lines.