M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 1-wire type, 16 points/common; with socket)

FA-TH16YTL11S

Features

  • Product overview:
    Digital signals from a programmable controller can be converted to
    signals suitable for the connected devices such as a magnetic starter
    (example: from 24VDC signal to 200VAC signal).
    One terminal module supports connections with multiple devices with
    different voltage loads.
    Merit.1
    This module converts the input from the MELSEC sink-type transistor output module to 1.0A transistor output.
    Merit.2
    When a 64-point output module is used, output conversion for a maximum of 64 points can be made per one slot.
    Merit.3
    Sockets enable transistor modules to be replaced individually. (Easy maintenance)
Sales status On sale

Basic specifications

Item Specifications
Model FA-TH16YTL11S
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC iQ-F
MELSEC-Q
MELSEC-F
MELSEC-L
Product category Digital signal converter (terminal module)
Terminal block type Screw terminal type
Delivery date -

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location *2 Inside the control panel (Indoor use)
Overvoltage category *3 II or less
Pollution degree *4 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 Install the module in a control panel that satisfies both of the following: a protection degree of IP20, UL50 Type 1 or higher. Design the control panel suitable for the environment if necessary.
*3 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*4 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
Connected programmable
controller
Sink-type 24VDC transistor output module
Terminal output type Sink output
No. of points 16
Isolation method Photocoupler
Rated load voltage 3 to 30VDC
Maximum number of simultaneous on points Depends on the load current characteristics below.
Minimum load current 1.0mA
Maximum load current 1.0A/point, 8A/common
Maximum inrush current 3A 10ms
Leakage current at off 0.1mA or lower (at 30VDC)
Maximum voltage drop at ON 1.5V or less
Response time ( Off → On ) 1ms or less
Response time ( On → Off ) 1ms or less
Surge suppressor Zener diode (built in transistor module)
Fuse None
Wiring method for common 16 points/common (1-wire type)
External power supply 24VDC+-10% (ripple ratio: within 5%)
Module current consumption Approx. 160mA at 24VDC (not including current consumption of programmable controller)
Withstand voltage, insulation resistance Between inputs/outputs: 2500VAC for 1 minute, 10MΩ or more
Noise immunity Simulator noise 500Vp-p, noise width 1us
(based on a noise simulator with a noise frequency of 25 to 60Hz)
Operation display LED on with power supply on and output on
Socket Provided (transistor module replaceable)
No. of times to replace module 50 times
Module mixing Not possible
Terminal block M3 spring-up screws, number of terminals: 20P, 7.62mm pitch
Applicable wire,
tightening torque
0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N·cm (6 to 9kgf·cm)
Module installation ( Screw type ) M4 × 0.7mm × 22mm or more, tightening torque: 78 to 118N·cm (8 to 12kgf·cm)
Module instALlation ( DIN rail ) TH35-7.5Fe, TH35-7.5AL (IEC 60715 compliant)
Accessory Module extraction tool
Weight Approx. 230g
Precautions When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Digital Signal Converters (Terminal Modules)(3MB) English MEIC224E_226-C February 2025
数字信号转换器(终端模块)(3MB) Simplified Chinese MEIC234C_236-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User's Manual(8MB) English 50D-FG0232E-E June 2022
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023

Technical information(Technical News)

* The table can be scrolled to the right.

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview
FA-CBL50YM20 5m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20M20 2m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10YM20 1m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10M20 1m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06M20 0.6m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06TMV20 0.6m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20TMV20 2m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10TMV20 1m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30TMV20 3m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30YM20 3m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20YM20 2m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50MMH20 5m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30MMH20 3m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2H 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FM2H 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2H 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FM2V 5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL30FM2V 3m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL100FM2V 10m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL03FM2H 0.3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06MMH20 0.6m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20MMH20 2m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10MMH20 1m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2LH 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FM2LH 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FM2LH 5m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2LH 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FM2LV 1m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06FM2LV 0.6m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FM2LV 5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2LV 3m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100FM2LV 10m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2LV 2m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06FM2V 0.6m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL10FM2V 1m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL15FM2V 1.5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL20FM2V 2m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.

Related products

MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
FA-LEB16XY-D

The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.

MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
FA-LEB16XY

The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.

M3.5-screw, module type, 16-point N/C contact relay output (independent common; with socket)
FA-TH16YRAB20SL

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point C/O contact relay output (independent common; with socket)
FA-TH16YRAC20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Module extraction tool
FA-PULL10

These tools are used to pull out modules from a socket-type terminal module.

MELSEC-dedicated 16-point 1-wire type
FA-TB16XY

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

M3.5-screw, module type, 16-point N/O contact relay output(independent common; with socket)
FA-TH16YRA20SL

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw 16-point 2.0A transistor output (sink-type to sink/source-type, independent common)
FA-TH16Y2TR20

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Replacement module
FA-SN24D01HZS4

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 2-wire type, 16 points/common; with socket)
FA-TH16YTL21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink/source-type, independent common; with socket)
FA-TH16YTR20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to source-type, 1-wire type, 16 points/common; with socket)
FA-TH16YTH11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (independent common; with socket)
FA-TH16YRA20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output(1-wire type, 16 points/common; with socket)
FA-TH16YRA11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output(1-wire type, 16 points/common; with socket)
FA-TH16YSR11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (2-wire type, 16 points/common; with socket)
FA-TH16YRA21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (1-wire type, 16 points/common)
FA-TH16YRA11

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (independent common)
FA-TH16YRA20

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output
(2-wire type, 16 points/common)
FA-TH16YRA21

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output (2-wire type, 16 points/common; with socket)
FA-TH16YSR21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output (independent common; with socket)
FA-TH16YSR20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point N/O contact relay output (sink-type to sink-type, independent common; with socket)
FA1-TH16Y2RA20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

MELSEC-dedicated 16-point 1-wire type
FA1-TE1SV16XY

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

Spring clamp type, module type, 16-point 1.0A triac output (sink-type to sink-type, independent common; with socket)
FA1-TH16Y1SR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point 1.0A transistor output
(sink-type to sink-type, independent common; with socket)
FA1-TH16Y1TR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point socket module(sink-type to sink-type, independent common)
FA1-TH16Y2SC20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

MELSEC-dedicated 16-point 3-wire type (16 points/8 (24V) common points + 8 (0V) common points)
FA-TB16XYPN

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

MELSEC-dedicated 16-point 3-wire type
(16 points/16 (24V) common points + 16 (0V) common points)
FA-TB16XYPN3

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.