MELSEC-dedicated 16-point 3-wire type (16 points/8 (24V) common points + 8 (0V) common points)

FA-TB16XYPN

Features

  • Product overview:
    The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
    Merit.1
    This product is used to branch the 32-point connectors of a MELSEC connector-type I/O module into 16-point units by using a branch cable, and used separately from another 16-point module.
    Merit.2
    As the product has two common terminals (24V and 0V) per two signal terminals, an external common terminal block is not required.
    Merit.3
    Cross-head screws of terminals are spring-up screws, making round solderless terminal installation easy.
    Merit.4
    The Mitsubishi Electric programmable controller input/output signal (0 to F) numbers are indicated on the marking strip, making wiring easy.
    Merit.5
    The module can be installed using a DIN rail or screws.
Sales status On sale

Basic specifications

Item Specifications
Model FA-TB16XYPN
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC iQ-F
MELSEC-Q
MELSEC-F
MELSEC-L
Product category Junction terminal block for programmable controller
Terminal block type Screw terminal type

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 84Hz : Half amplitude 3.5mm
84 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 84Hz : Half amplitude 1.75mm
84 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside control panel
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
Rated voltage 24VDC
Voltage 28.8VDC
Current 1A (each signal terminal), 2A (each power supply terminal)
Wiring method for common points/8 (24V) common points + 8 (0V) common point
Terminal block : Terminal screw M3 screws, number of terminals: 34P, 7.62mm pitch, spring-up screw with finger protection cover
Terminal block : Applicable wire, tightening torque 0.3 to 2mm2 (with solderless terminal used), 58.8 to 88.2N-cm (6 to 9kgf-cm)
Installation method : Screw type M4 × 0.7mm × 12mm or more, tightening torque: 78 to 118N-cm (8 to 12kgf-cm)
Installation method : DIN rail Applicable DIN rails: TH35-7.5Fe, TH35-7.5AL (IEC 60715 compliant)
No. of points 16
I/O device No. X0 to XF or Y0 to YF
Withstand voltage, insulation resistance 500VAC for 1 minute, 100MΩ or more (between all DC external terminals and ground, between charged areas)
Weight Approx. 180g
Precautions X or Y of the input/output device number is X when an input module is connected, and Y when an output module is connected. The number is determined by the slot where the I/O module is inserted.
When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
User's Manual(998KB) English 50D-FG0230E-A March 2018

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview
FA-CBL20DM2FY 2m For MELSEC source output (D-Sub 37P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30TMV20 3m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20TMV20 2m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50YM20 5m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06MMH20 0.6m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10MMH20 1m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20MMH20 2m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30MMH20 3m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50MMH20 5m For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100FM2V 10m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL10FM2H 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2H 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2H 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL15FM2V 1.5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL20FM2V 2m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL30FM2V 3m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL50FM2V 5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL06FM2V 0.6m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL10FM2V 1m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block.
FA-CBL10TMV20 1m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06M20 0.6m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10M20 1m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10YM20 1m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20M20 2m For MELSEC terminal block I/O (discrete cable and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20YM20 2m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30YM20 3m For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2LV 2m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2LV 3m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FM2LV 5m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL100FM2LV 10m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FM2LH 1m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20FM2LH 2m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06FM2LV 0.6m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10FM2LV 1m For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL06TMV20 0.6m For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30FM2LH 3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL50FM2LH 5m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL03FM2H 0.3m For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.

Related products

MELSEC-dedicated 16-point 1-wire type
FA1-TE1SV16XY

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
FA-LEB16XY-D

The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.

MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
FA-LEB16XY

The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.

MELSEC-dedicated 16-point 1-wire type
FA-TB16XY

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

MELSEC-dedicated 16-point 3-wire type
(16 points/16 (24V) common points + 16 (0V) common points)
FA-TB16XYPN3

The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.

Spring clamp type, 16 points, independent (positive common), Unit with relay modules (24 V DC, NO contact)
FA1-TH16X24RA1L20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, 4 points, independent, Base unit (user-selectable modules)
FA1-TH4X2SC20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, 8 points, independent, Base unit (user-selectable modules)
FA1-TH8X2SC20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, 16 points, independent (negative common), Unit with relay modules (24 V DC, NO contact)
FA1-TH16X24RA1H20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw 16-point 200VAC photocoupler input (2-wire type, 16 points/common)
FA-TH16X200A31

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw 16-point 100VAC photocoupler input (2-wire type, 16 points/common)
FA-TH16X100A31

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw 16-point 24VDC photocoupler input (2-wire type, 16 points/common)
FA-TH16X24D31

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point C/O contact relay output (independent common; with socket)
FA-TH16YRAC20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 24VDC N/O contact relay input
(independent common; with socket)
FA-TH16XRA20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 1-wire type, 16 points/common; with socket)
FA-TH16YTL11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 2-wire type, 16 points/common; with socket)
FA-TH16YTL21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to source-type, 1-wire type, 16 points/common; with socket)
FA-TH16YTH11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (independent common)
FA-TH16YRA20

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output(1-wire type, 16 points/common; with socket)
FA-TH16YRA11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (independent common; with socket)
FA-TH16YRA20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output
(2-wire type, 16 points/common)
FA-TH16YRA21

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (2-wire type, 16 points/common; with socket)
FA-TH16YRA21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output(1-wire type, 16 points/common; with socket)
FA-TH16YSR11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output (independent common; with socket)
FA-TH16YSR20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A triac output (2-wire type, 16 points/common; with socket)
FA-TH16YSR21S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink/source-type, independent common; with socket)
FA-TH16YTR20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (source-type to source-type, 1-wire type, 16 points/common; with socket)
FA-THE16YTH11S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point 1.0A transistor output (source-type to sink/source-type, independent common; with socket)
FA-THE16YTR20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw 16-point 200VAC photocoupler input (2-wire type, 16 points/common)
FA-TH16X200A31L
FA-TH16X200A31L

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw 16-point 2.0A transistor output (sink-type to sink/source-type, independent common)
FA-TH16Y2TR20

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw 16-point 100VAC photocoupler input (2-wire type, 16 points/common)
FA-TH16X100A31L

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw 16-point 24VDC photocoupler input (2-wire type, 16 points/common)
FA-TH16X24D31L

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw 16-point 100VDC photocoupler input (2-wire type, 16 points/common)
FA-TH16X100D31L

Positive common, 24VDC input module

M3.5-screw, module type, 16-point N/O contact relay output(independent common; with socket)
FA-TH16YRA20SL

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw 16-point 48VDC photocoupler input (2-wire type, 16 points/common)
FA-TH16X48D31L

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3.5-screw, module type, 16-point N/C contact relay output (independent common; with socket)
FA-TH16YRAB20SL

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (1-wire type, 16 points/common)
FA-TH16YRA11

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

M3-screw, module type, 16-point N/O contact relay output (independent common; with socket)
FA1-TH1E16Y2RA20S

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point N/O contact relay output (sink-type to sink-type, independent common; with socket)
FA1-TH16Y2RA20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point 1.0A triac output (sink-type to sink-type, independent common; with socket)
FA1-TH16Y1SR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point N/O contact relay output (source-type to source-type, independent common; with socket)
FA1-TH1E16Y2RA20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point socket module (source-type to source-type, independent common)
FA1-TH1E16Y2SC20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point socket module(sink-type to sink-type, independent common)
FA1-TH16Y2SC20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point 1.0A triac output (source-type to source-type, independent common; with socket)
FA1-TH1E16Y1SR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point 1.0A transistor output
(sink-type to sink-type, independent common; with socket)
FA1-TH16Y1TR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.

Spring clamp type, module type, 16-point 1.0A transistor output (source-type to source-type, independent common; with socket)
FA1-TH1E16Y1TR20S1E

Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.