[Output type] Module installation base unit

FA1-AT1B4Y1TB

Features

  • Product overview:
    Analog signals from the connected devices such as sensors can be
    converted to signals suitable for a programmable controller (example:
    from a temperature signal to a voltage signal).
    Data from sensors can be visualized easily, and small-scale IoT can be
    introduced.
    Merit.1
    Thick wires such as compensating lead wires can be directly connected.
    Merit.2
    Isolation between channels enables mixing of output modules.
Sales status On sale

Basic specifications

Item Specifications
Model FA1-AT1B4Y1TB
Category Time and wire saving devices
Connected device Programmable controller
Series of connected devices MELSEC iQ-R
MELSEC-Q
MELSEC-L
MELSEC iQ-F
MELSEC-F
CC-Link IE TSN
CC-Link IE Field
CC-Link
Other PLC
Computers from various manufacturers
Product category Analog signal converter
Terminal block type Screw terminal type
Delivery date -

Specifications

General specifications

Item Specifications
Operating ambient temperature 0 to 55℃
Storage ambient temperature -25 to 75℃
Operating ambient humidity 5 to 95%RH, no condensation
Storage ambient humidity 5 to 95%RH, no condensation
Vibration resistance ( With intermittent vibration ) 5 to 8.4Hz : Half amplitude 3.5mm
8.4 to 150Hz : Acceleration 9.8m/s2
Number of sweeps : 10 times in each direction X, Y, and Z
Vibration resistance ( With continual vibration ) 5 to 8.4Hz : Half amplitude 1.75mm
8.4 to 150Hz : Acceleration 4.9m/s2
Shock resistance 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2)
Operating atmosphere Free of corrosive gases
Operating altitude *1 2000m or less
Installation location Inside the control panel(Indoor use)
Overvoltage category *2 II or less
Pollution degree *3 2 or less
Precautions *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using
the module under pressure, please consult your local Mitsubishi Electric representative.
*2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive
pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.


Product specifications

Item Specifications
No. of slots 4
Terminal block : Terminal screw M3 spring-up screws, 7.62mm pitch
Terminal block : Applicable wire,
tightening torque
0.3 to 2mm2 (with solderless terminal used),
58.8 to 88.2N・cm (6 to 9kgf・cm)
Module installation : Screw type M4 × 0.7mm × 20mm or more
Tightening torque: 78 to 118N・cm (8 to 12kgf・cm)
Module installation : DIN rail Applicable DIN rails: TH35-7.5Fe, TH35-7.5Al (IEC 60715 compliant)
Power supply 24VDC+-10%
Current consumption (24VDC) 6mA or less
(not including current consumption of modules)
Withstand voltage, insulation resistance Between input, output, and power supply: 500VAC for 1 minute, 10MΩ or more
Weight Approx. 220g
Precautions Mount a dummy module into an unused slot to allow no empty slot.
When connecting cables to the module, push the cable connector until it is locked. Failure to do so may cause poor contact.
When connecting the product with a programmable controller, confirm that the product configuration is correct.
Connection based on a wrong configuration may cause a failure or malfunction.
output type modules (line color: orange) only can be mounted. Mounting an Input type module may cause a failure or malfunction.

External Dimensions・Product CAD Data

External Dimensions

Product CAD Data

Wiring diagrams and connection examples・Note

Wiring diagrams and connection examples

N/A

Name Filename

Other Technical Information

N/A

Name Filename

Precautions for use

N/A

Name Filename

Catalogs・New Product Releases

* The table can be scrolled to the right.

Name Language Document No. Release date
Analog Signal Converters(2MB) English MEIC220E_21Y-B February 2025
模拟信号转换器 (2MB) Simplified Chinese MEIC235C_23X-A February 2025
FA Goods General Catalog Digest edition(28MB) English MEIC198E_209-B March 2024
FA关联产品 综合目录 摘要版(29MB) Simplified Chinese MEIC199C_209-B March 2024
FA Goods General Catalog Time and Wire Saving Devices(79MB) English MEIC202E_20Z-E November 2024

Manual

* The table can be scrolled to the right.

Name Language Document No. Release date
EMC and Low Voltage Directives Compliant Manual(256KB) English 50D-FA9010-108E-G December 2023
User’s Manual(1MB) English 50D-FA9010-123E-F December 2023

Technical information(Technical News)

N/A

* The table can be scrolled to the right.

Name Language Document No. Release date

Downloads

N/A

Profile/module FB (function block)

Name Filename

Control & Communication System Profile CSP+

Name Filename

Sample program

Name Filename

Video

N/A

Related products

Connection cables

Model Length Name Overview
FA-CBL10ATQ8YT 1.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20ATQ8YT 2.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATQ8YT 3.0m [Output type] Connection cable with MELSEC-Q Series terminal block Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL10ATQ8YA 1.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL20ATQ8YA 2.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATQ8YA 3.0m [Output type] Connection cable with connector Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA1-CB2L10AT4YA1T 1m [Output] 4-channel, cable with screw terminal block This is a cable used to connect a programmable controller and an analog signal converter.
FA1-CB2L20AT4YA1T 2m [Output] 4-channel, cable with screw terminal block This is a cable used to connect a programmable controller and an analog signal converter.
FA-CBL10ATYF 1.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA1-CB2L30AT4YA1T 3m [Output] 4-channel, cable with screw terminal block This is a cable used to connect a programmable controller and an analog signal converter.
FA-CBL20ATYF 2.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA-CBL30ATYF 3.0m [Output type] Connection cable with discrete cable on one side Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable.
FA2-CB2L10AT4YA1E 1m [Output] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.This is a cable used to connect a programmable controller and an analog signal converter.
FA2-CB2L20AT4XV1E 2m [Input] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.
FA2-CB2L30AT4YA1E 3m [Output] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.This is a cable used to connect a programmable controller and an analog signal converter.
FA3-CB2L10AT4YA1E 1m [Output] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.This is a cable used to connect a programmable controller and an analog signal converter.
FA3-CB2L20AT4YA1E 2m [Output] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.This is a cable used to connect a programmable controller and an analog signal converter.
FA3-CB2L30AT4YA1E 3m [Output] 4-channel, cable with spring clamp terminal block This is a cable used to connect a programmable controller and an analog signal converter.This is a cable used to connect a programmable controller and an analog signal converter.
FA1-CB2L05AT4EX 0.5m Connection cable for 4-channel installation base unit extension This is a cable used to extend an analog signal converter.
FA1-CB2L10AT4EX 1m Connection cable for 4-channel installation base unit extension This is a cable used to extend an analog signal converter.
FA1-CB2L20AT4EX 2m Connection cable for 4-channel installation base unit extension This is a cable used to extend an analog signal converter.
FA1-CB2L30AT4EX 3m Connection cable for 4-channel installation base unit extension This is a cable used to extend an analog signal converter.

Related products

[Output type] Module installation base unit
FA1-AT1B4Y1TE

Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.

[Input/output type] Signal pass-through module
FA-ATFTMXY

Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.

[Input/output type] Dummy module
FA-ATNDM5

Analog signals from the connected devices such as sensors can be
converted to signals suitable for a programmable controller (example:
from a temperature signal to a voltage signal).
Data from sensors can be visualized easily, and small-scale IoT can be
introduced.

Extension cable for connection with signal converter
FA3-CB2L10MM1H20

Extension cable for connection with signal converter

Extension cable for connection with signal converter
FA3-CB2L20MM1H20

Extension cable for connection with signal converter

Extension cable for connection with signal converter
FA3-CB2L30MM1H20

Extension cable for connection with signal converter

CC-Link IE TSN/Ethernet network interface module for analog signal converter
FA3-AT1T8Y-01C

Connecting the analog signal converter through a network to collect data from devices enables small-scale IoT.

CC-Link IE TSN/Ethernet network interface module for analog signal converter
FA3-AT1T8Y

Connecting the analog signal converter through a network to collect data from devices enables small-scale IoT.

CC-Link network interface module for analog signal converter
FA3-AT1C8Y-01C

Connecting the analog signal converter through CC-Link to collect data from devices enables small-scale IoT.

CC-Link network interface module for analog signal converter
FA3-AT1C8Y

Connecting the analog signal converter through CC-Link to collect data from devices enables small-scale IoT.