- MELSEC-dedicated Input/output 16 points, 24VDC
FA1-TE2SV16XY
- Features
- Specifications
- External Dimensions・
Product CAD Data - Wiring diagrams and connection examples・
Note - Catalogs・
New Product Releases - Manual
- Technical information
(Technical News) - Downloads
- Video
- Related products
Features
-
- Product overview:
- The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- Merit.1
- Various connection cables connecting MELSEC series modules, CNCs ( computerized numerical controllers ), and non-Mitsubishi PLCs are available.
- Merit.2
- Using ferrule terminals enables push-in connections.

| Sales status | On sale |
|---|
Basic specifications
| Item | Specifications | |
|---|---|---|
| Model | FA1-TE2SV16XY | |
| Category | Time and wire saving devices | |
| Connected device | Programmable controller | |
| Series of connected devices | MELSEC iQ-R | |
| MELSEC iQ-F | ||
| MELSEC-Q | ||
| MELSEC-L | ||
| MELSEC-F | ||
| Product category | Junction terminal block for programmable controller | |
| Terminal block type | Spring clamp terminal type | |
Specifications
General specifications
| Item | Specifications | |
|---|---|---|
| Operating ambient temperature | 0 to 55℃ | |
| Storage ambient temperature | -25 to 75℃ | |
| Operating ambient humidity | 5 to 95%RH, no condensation | |
| Storage ambient humidity | 5 to 95%RH, no condensation | |
| Vibration resistance ( With intermittent vibration ) | 5 to 8.4Hz : Half amplitude 3.5mm | |
| 8.4 to 150Hz : Acceleration 9.8m/s2 | ||
| Number of sweeps : 10 times in each direction X, Y, and Z | ||
| Vibration resistance ( With continual vibration ) | 5 to 8.4Hz : Half amplitude 1.75mm | |
| 8.4 to 150Hz : Acceleration 4.9m/s2 | ||
| Shock resistance | 147m/s2, 3 times in each direction X, Y, and Z(Applicable standards : JIS B 3502, IEC61131-2) | |
| Operating atmosphere | Free of corrosive gases | |
| Operating altitude *1 | 2000m or less | |
| Installation location | Inside the control panel *4, Indoor use | |
| Overvoltage category *2 | II or less | |
| Pollution degree *3 | 2 or less | |
| Precautions | *1 Do not use or store the module under pressure higher than the atmospheric pressure at an altitude of 0 meters. Doing so may cause malfunction. When using the module under pressure, please consult your local Mitsubishi Electric representative. |
|
| *2 This indicates the assumption that the equipment is connected to a power distribution system, ranging from a public electrical power distribution network down to machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for equipment with the rated voltage of up to 300V is 2500V. | ||
| *3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used. In pollution degree 2, only nonconductive pollution occurs. A temporary conductivity caused by condensation must be expected occasionally. |
||
| *4 The enclosure is suitably designed for those specific environmental conditions, as applicable, and enclosure rate meets IP20 and minimum type 1 of UL 50. | ||
Product specifications
| Item | Specifications | |
|---|---|---|
| Rated voltage | 24VDC (SELV and LIM or Class 2) *1 | |
| Maximum operating voltage | 30VDC (SELV and LIM or Class 2) *1 | |
| Maximum operating current | Signal: 1A, Common: 2A *2 | |
| Wiring method for common | 16 points / 2 (24V)common points +2 (0V) common points | |
| Terminal block : Number of terminals | 20P | |
| Terminal block : Wire strip length | 8mm | |
| Module installation | Applicable DIN rail: TH35-7.5Fe, TH35-7.5Al (IEC 60715 compliant) | |
| Withstand voltage, insulation resistance | 1250VAC for 1 minute (between all terminals and case) ,10MΩ or more (measured with 500VDC insulation resistance tester) | |
| Applicable wire:Without ferrule(stranded/solid wire) | 0.2 to 1.5mm2 (24 to 16AWG),copper wire with a temperature rating of 75°C or more *3,4,5 | |
| Applicable wire:Without ferrule(stranded wire) | 0.08 to 0.75mm2 (28 to 18AWG),copper wire with a temperature rating of 75°C or more | |
| Weight | 約40g | |
| Precautions | *1:The power supply must use CLASS2 power supply or a power supply to the SELV (Safety Extra-Low Voltage) and LIM (Limited Energy Circuit) circuit. | |
| *2:Evaluation for UL certification is conducted under resistance load conditions. | ||
| *3:Select wires depending on the current value used. | ||
| *4:Use coper wires having temperature rating of 75°C or more for the terminal block. | ||
| *5:For UL certification, suitable for field wiring when a ferrule is not used. | ||
External Dimensions・Product CAD Data
External Dimensions
Product CAD Data
Wiring diagrams and connection examples・Note
Wiring diagrams and connection examples
N/A
| Name | Filename |
|---|
Other Technical Information
N/A
| Name | Filename |
|---|
Precautions for use
N/A
| Name | Filename |
|---|
Catalogs・New Product Releases
* The table can be scrolled to the right.
| Name | Language | Document No. | Release date |
|---|---|---|---|
| Junction Terminal Block Spring Clamp Terminal Type(1MB) | English | MEIC232E_234 | April 2023 |
| FA Goods General Catalog Digest edition(23MB) | English | MEIC198E_209-C | October 2025 |
| FA关联产品 综合目录 摘要版(23MB) | Simplified Chinese | MEIC199C_209-C | October 2025 |
| FA Goods General Catalog Time and Wire Saving Devices(82MB) | English | MEIC202E_20Z-F | October 2025 |
Manual
* The table can be scrolled to the right.
| Name | Language | Document No. | Release date |
|---|---|---|---|
| User's Manual(1MB) | English | 50D-FG0672-B | November 2023 |
Technical information(Technical News)
N/A
* The table can be scrolled to the right.
| Name | Language | Document No. | Release date |
|---|
Downloads
N/A
Profile/module FB (function block)
| Name | Filename |
|---|
Control & Communication System Profile CSP+
| Name | Filename |
|---|
Sample program
| Name | Filename |
|---|
Video
N/A
Related products
Connection cables
| Model | Length | Name | Overview |
|---|---|---|---|
| FA-CBL06FM2V | 0.6m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL10FM2V | 1m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL20FM2V | 2m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL30FM2V | 3m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL50FM2V | 5m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL100FM2V | 10m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | A round 40-core cable is pulled out from a MELSEC series FCN 40P connector type I/O module. The other cable end branches into two MIL 20P connectors, each of which is connected to a MELSEC-dedicated 16-point terminal block. |
| FA-CBL03FM2H | 0.3m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10FM2H | 1m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20FM2H | 2m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30FM2H | 3m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on MIL 20P connector side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL06FM2LV | 0.6m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10FM2LV | 1m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20FM2LV | 2m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30FM2LV | 3m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL50FM2LV | 5m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL100FM2LV | 10m | For MELSEC positive common input/sink output (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10FM2LH | 1m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20FM2LH | 2m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30FM2LH | 3m | For positive common input/sink output of Mitsubishi Electric CC-Link remote I/O module (FCN 40P connector and two MIL 20P connectors, branching on programmable controller side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL06MMH20 | 0.6m | For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10MMH20 | 1m | For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20MMH20 | 2m | For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30MMH20 | 3m | For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL50MMH20 | 5m | For Mitsubishi Electric CC-Link/LT remote I/O module (MIL 20P connector and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20DM2FY | 2m | For MELSEC source output (D-Sub 37P connector and two MIL 20P connectors, branching on MIL 20P connector side) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10M20 | 1m | For MELSEC terminal block I/O (discrete cable and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20M20 | 2m | For MELSEC terminal block I/O (discrete cable and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10YM20 | 1m | For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20YM20 | 2m | For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30YM20 | 3m | For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL50YM20 | 5m | For MELSEC terminal block I/O (Y-shaped solderless terminals and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL06TMV20 | 0.6m | For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL10TMV20 | 1m | For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL20TMV20 | 2m | For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
| FA-CBL30TMV20 | 3m | For MELSEC terminal block I/O (MELSEC-Q terminal block and MIL 20P connector) | Easy wiring, reducing wiring time : A programmable controller and a junction terminal block can be easily wired using the dedicated cable. |
Related products
- M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 1-wire type, 16 points/common; with socket)
- FA-TH16YTL11S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink-type, 2-wire type, 16 points/common; with socket)
- FA-TH16YTL21S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A transistor output (sink-type to source-type, 1-wire type, 16 points/common; with socket)
- FA-TH16YTH11S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A transistor output (sink-type to sink/source-type, independent common; with socket)
- FA-TH16YTR20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- MELSEC-dedicated 16-point 3-wire type (16 points/8 (24V) common points + 8 (0V) common points)
- FA-TB16XYPN
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- MELSEC-dedicated 16-point 3-wire type
(16 points/16 (24V) common points + 16 (0V) common points) - FA-TB16XYPN3
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- MELSEC-dedicated Input/output 32 points, 24VDC
- FA1-TE2SD32XY
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- M3-screw, module type, 16-point N/O contact relay output (independent common)
- FA-TH16YRA20
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output(1-wire type, 16 points/common; with socket)
- FA-TH16YRA11S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output (1-wire type, 16 points/common)
- FA-TH16YRA11
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output
(2-wire type, 16 points/common) - FA-TH16YRA21
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output (independent common; with socket)
- FA-TH16YRA20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A triac output (independent common; with socket)
- FA-TH16YSR20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output (2-wire type, 16 points/common; with socket)
- FA-TH16YRA21S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A triac output(1-wire type, 16 points/common; with socket)
- FA-TH16YSR11S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A triac output (2-wire type, 16 points/common; with socket)
- FA-TH16YSR21S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 8 points, independent, Base unit (user-selectable modules)
- FA1-TH8X2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A transistor output (source-type to sink/source-type, independent common; with socket)
- FA-THE16YTR20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 16 points, independent (positive common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH16X24RA1L20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 16 points, independent (negative common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH16X24RA1H20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 4 points, independent, Base unit (user-selectable modules)
- FA1-TH4X2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3.5-screw 16-point 200VAC photocoupler input (2-wire type, 16 points/common)
FA-TH16X200A31L - FA-TH16X200A31L
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 4-point socket module(sink-type to sink-type, independent common)
- FA1-TH4Y2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3.5-screw 16-point 24VDC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X24D31L
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3.5-screw 16-point 100VDC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X100D31L
Positive common, 24VDC input module
- M3.5-screw 16-point 48VDC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X48D31L
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3.5-screw, module type, 16-point N/C contact relay output (independent common; with socket)
- FA-TH16YRAB20SL
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 8 points, independent (negative common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH8X24RA1H20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a Push-button switch.
One terminal module can be connected to different loads of common.
- M3.5-screw, module type, 16-point N/O contact relay output(independent common; with socket)
- FA-TH16YRA20SL
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 8-point socket module(sink-type to sink-type, independent common)
- FA1-TH8Y2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 1.0A transistor output (source-type to source-type, 1-wire type, 16 points/common; with socket)
- FA-THE16YTH11S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point socket module (source-type to source-type, independent common)
- FA1-TH1E16Y2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, 16 points, independent (negative common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH4X24RA1H20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a Push-button switch.
One terminal module can be connected to different loads of common.
- Spring clamp type, 4 points, independent (plus common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH4X24RA1L20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a Push-button switch.
One terminal module can be connected to different loads of common.
- Spring clamp type, 8 points, independent (plus common), Unit with relay modules (24 V DC, NO contact)
- FA1-TH8X24RA1L20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a Push-button switch.
One terminal module can be connected to different loads of common.
- M3.5-screw 16-point 100VAC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X100A31L
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- MELSEC-dedicated 16-point 1-wire type
- FA-TB16XY
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- M3-screw 16-point 100VAC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X100A31
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw 16-point 200VAC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X200A31
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point N/O contact relay output (independent common; with socket)
- FA1-TH1E16Y2RA20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point N/O contact relay output (sink-type to sink-type, independent common; with socket)
- FA1-TH16Y2RA20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point N/O contact relay output (source-type to source-type, independent common; with socket)
- FA1-TH1E16Y2RA20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw 16-point 2.0A transistor output (sink-type to sink/source-type, independent common)
- FA-TH16Y2TR20
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point 1.0A triac output (sink-type to sink-type, independent common; with socket)
- FA1-TH16Y1SR20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw 16-point 24VDC photocoupler input (2-wire type, 16 points/common)
- FA-TH16X24D31
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point 1.0A transistor output
(sink-type to sink-type, independent common; with socket) - FA1-TH16Y1TR20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point 1.0A triac output (source-type to source-type, independent common; with socket)
- FA1-TH1E16Y1SR20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point 1.0A transistor output (source-type to source-type, independent common; with socket)
- FA1-TH1E16Y1TR20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- Spring clamp type, module type, 16-point socket module(sink-type to sink-type, independent common)
- FA1-TH16Y2SC20S1E
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
- FA-LEB16XY
The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.
- M3-screw, module type, 16-point C/O contact relay output (independent common; with socket)
- FA-TH16YRAC20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- M3-screw, module type, 16-point 24VDC N/O contact relay input
(independent common; with socket) - FA-TH16XRA20S
Digital signals from a programmable controller can be converted to
signals suitable for the connected devices such as a magnetic starter
(example: from 24VDC signal to 200VAC signal).
One terminal module supports connections with multiple devices with
different voltage loads.
- MELSEC-dedicated 16-point 3-wire open type with 4-pole connector
- FA-LEB16XY-D
The junction terminal block helps signal transmissions between a
programmable controller and devices such as sensors in connection
methods suitable for applications.
- General-purpose Input/output 20 points, 24VDC
- FA1-TE2SV20P
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- General-purpose Input/output 40 points, 24VDC
- FA1-TE2SD40P
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- Spring clamp terminal block conversion adapter
- FA1-TE40PA
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.
- Common terminal block 40 points, 24VDC/100 to 240VAC
- FA1-TE2SV40EX
The junction terminal block helps signal transmissions between a programmable controller and devices such as sensors in connection methods suitable for applications.